Compatible Material
Concrete
ICC Approved for Cracked Concrete
Yes
Minimum Installation Depth
80 mm
Maximum Material Thickness
20 mm
Ultimate Shear Strength (4,000 psi Concrete)
18,849 lb
Ultimate Tension Strength (4,000 psi Concrete)
9,988 lb
Allowable Shear in 2500 PSI Uncracked Concrete (Lbs.)
4751
Allowable Tension in 2500 PSI Uncracked Concrete (Lbs.)
3114
Allowable Tension in 6500 PSI Uncracked Concrete (Lbs.)
5008
Allowable Tension in 6500 PSI Cracked Concrete (Lbs.)
3547
Embedment In Concrete
80 mm
Allowable Shear in 6500 PSI Cracked Concrete (Lbs.)
6597
Allowable Tension in 2500 PSI Cracked Concrete (Lbs.)
2206
Allowable Shear in 2500 PSI Cracked Concrete (Lbs.)
4751
Allowable Shear in 6500 PSI Uncracked Concrete (Lbs.)
6597
Thread Length
Not Applicable
ICC Approved for Un-Cracked Concrete
Yes
Industry Standards
ACI 355.2/ETA-02-0030
Wedge Anchor Type
Seismic Wedge Anchor
System of Measurement
Metric
Material Grade/Class
Class 8.8
Minimum Ultimate Shear Strength
5,620 lb
Minimum Ultimate Tension Strength
3,765 lb
Maximum Ultimate Shear Strength
44,623 lb
Eyelet Hole Size
Not Applicable
Maximum Ultimate Tension Strength
21,444 lb
Minimum Installation Torque
59 ft-lb
Maximum Installation Torque
59 ft-lb
Washer Outside Diameter
30 mm
Minimum Material Thickness
177 51/64 mm
Material Quality Standards
ACI 318 Category 1
Manufacturer Location
Made in USA
Country of Origin (subject to change)
Germany