Enclosure Height (In.)
8 3/4 in
Enclosure Width (In.)
10 1/2 in
Enclosure Depth (In.)
6 in
Input Voltage
110V AC 50/60 Hz
Agency Compliance
ETL Listed
Max. Circuit Length (Ft.)
50 ft
Special Information
The WLC Series is perfect in any application where water level management is important such as cooling tower basins and water holding tanks for cooling towers. It uses a microprocessor that monitors all probes for correct operation and then provides the corresponding outputs to drive the power relays, the Building Automation System and a visual indication of the operational status. The Modular construction and a self-test feature insure user-friendly operation. By using a very low voltage and current, WLC Series sensors never foul or degrade
Special Features
110Vac Solenoid Required ( Purchase Seperately) Rated For Outdoor Installation, Building Automation Dry Contracts, Can Be Integrated Into Building Automation System, Compensates For Wave Action, Easy To Read Led Display, Low Voltage Probe, Modular Construction, No High Voltage In The Wet Area Of The System, No Moving Parts, One-Step Internal Testing System For The Electronics, Seperate Relay For Each Set Point, Stainless Steel Probes
Sensor Placement
On The Environment Wall or In A Static Pipe
Operating Range
1/2 and 6 in
Application
Cooling Towers, Water Water Tanks, Storm Water tanks, Sewage Water Systems, Well Water Holding tanks, Irrigation Lakes, Boilers, Water Storage Tanks
Sensors Included
Fill Height With Low Level Alarm
Valve
Can Be Used With 1 in Npt And 110Vac Or Eqivalent Made By Asco Model 8221
Includes
Installation Instructions, Mounting Brackets and U Bolts, Sensor Wire, Stainless Steel Sensor Assembly, Waterline Controller in NEMA 4x Box
Control Type
Electronic With Microprocessor For Site Automation or Integration
Sensor Cord Length (Ft.)
50 ft
Dry Contact Switch Action
Normally Open
Included Flood Protection Lockout
Flood Protection Lockout Not Included
Reference Probe Length
17 in
Electrical Lead Length
Not Applicable
Process Connection Type
NPT
Power Relay Current Rating
30 A
Power Relay Switch Action
Normally Closed, Normally Open
Inlet Pressure - Maximum
Not Applicable
Fill Start Probe Color
White
Probes Included
Fill Start, Fill Stop, Low Alarm, Reference
Process Connection Size
1 in
Dry Contact Relay Contact Form
SPST
Fill Start Probe Length
15 1/2 in
Reference Probe Color
Black
Power Relay Contact Form
DPDT
Housing Material
Polycarbonate
Low Alarm Probe Length
17 in
Low Alarm Probe Color
Brown
Outlet Pressure - Maximum
30 psi
Dry Contact Current Rating
0.5 A
Fill Stop Probe Length
14 in
High Alarm Probe Length
Not Applicable
Mounting Style
Mounting Assembly
Number of Indicator Lights
3
Operating Temperature - Maximum
200 Degrees F
High Alarm Probe Color
Not Applicable
Country of Origin (subject to change)
United States