Enclosure Height (In.)
8 3/4 in
Enclosure Width (In.)
10 1/2 in
Enclosure Depth (In.)
6 in
Input Voltage
110V AC 50/60 Hz
Sensor Cord Length (Ft.)
50 ft
Agency Compliance
ETL Listed
Control Type
Electronic With Microprocessor For Site Automation or Integration
Includes
Installation Instructions, Mounting Brackets and U Bolts, Sensor Wire, Stainless Steel Sensor Assembly, Waterline Controller in NEMA 4x Box
Application
Cooling Towers, Waste Water Tanks, Storm Water tanks, Sewage Water Systems, Well Water Holding tanks, Irrigation Lakes, Boilers, Water Storage Tanks
Sensor Placement
On The Environment Wall or In A Static Pipe
Special Features
110Vac Solenoid Required ( Purchase Seperately) Rated For Outdoor Installation, Building Automation Dry Contracts, Can Be Integrated Into Building Automation System, Compensates For Wave Action, Easy To Read Led Display, Low Voltage Probe, Modular Construction, No High Voltage In The Wet Area Of The System, No Moving Parts, One-Step Internal Testing System For The Electronics, Seperate Relay For Each Set Point, Stainless Steel Probes
Sensors Included
Fill Height Only
Valve
Can Be Used With 1 in Npt And 110Vac Or Eqivalent Made By Asco Model 8221
Special Information
The WLC Series is perfect in any application where water level management is important such as cooling tower basins and water holding tanks for cooling towers. It uses a microprocessor that monitors all probes for correct operation and then provides the corresponding outputs to drive the power relays, the Building Automation System and a visual indication of the operational status. The Modular construction and a self-test feature insure user-friendly operation. By using a very low voltage and current, WLC Series sensors never foul or degrade
Max. Circuit Length (Ft.)
50 ft
Power Relay Contact Form
DPDT
Number of Indicator Lights
2
High Alarm Probe Color
Not Applicable
Probes Included
Fill Start, Fill Stop, Reference
Dry Contact Current Rating
0.5 A
Process Connection Type
NPT
Inlet Pressure - Maximum
Not Applicable
Outlet Pressure - Maximum
30 psi
Power Relay Current Rating
30 A
Mounting Style
Mounting Assembly
Reference Probe Color
Black
Fill Stop Probe Length
14 in
Electrical Lead Length
Not Applicable
High Alarm Probe Length
Not Applicable
Fill Start Probe Color
White
Operating Temperature - Maximum
200 Degrees F
Dry Contact Relay Contact Form
SPST
Process Connection Size
1 in
Dry Contact Switch Action
Normally Open
Included Flood Protection Lockout
Flood Protection Lockout Not Included
Housing Material
Polycarbonate
Power Relay Switch Action
Normally Closed, Normally Open
Reference Probe Length
17 in
Fill Start Probe Length
15 1/2 in
Country of Origin (subject to change)
United States