Item
Universal plug-in relay - Zelio RUM - 3
AC Contact Rating - Relay
10A @ 250V AC
DC Contact Rating - Relay
10A @ 28V DC
Contact Form - Relay
3 C/O
Power Consumption - Relay
3 VA
Features
Lockable Test Button; Status LED
Standards
IEC 61810-1, CSA C22.2 No 14, UL 508
Maximum Switching Voltage
250 V IEC
Electrical Durability
100000 cycles resistive
Shock Resistance
10 gn 11 ms) in operation IEC 60068-2-27, 10 gn 11 ms) not operating IEC 60068-2-27
[Uimp] Rated Impulse Withstand Voltage
4 kV 1.2/50µs)
Reset Time
20 ms at nominal voltage
Ambient Air Temperature For Operation
-40-55°C
Device Presentation
complete product
Average Resistance
1700 Ohm 20°C +/- 15 %
Control Type
lockable test button
[Ithe] Conventional Enclosed Thermal Current
10 A -40-55°C
[Ui] Rated Insulation Voltage
250 V IEC, 300 V CSA, 300 V UL
Load Current
10 A 250 V AC, 10 A 28 V DC
Operating Position
any position
[Uc] Control Circuit Voltage
120 V AC 50/60 Hz
Vibration Resistance
3 gn +/- 1 mm 10-150 Hz)5 cycles in operation, 4 gn +/- 1 mm 10-150 Hz)5 cycles not operating
Rated Operational Voltage Limits
96...132 V AC
Product or Component Type
plug-in relay
Operating Rate
u003c= 18000 cycles/hour no-load, u003c= 1200 cycles/hour under load
Utilisation Coefficient
0.2
Mechanical Durability
5000000 cycles
Average Coil Consumption In VA
3-3 60 Hz
Ip Degree of Protection
IP40
Test Levels
level A group mounting
Drop-Out Voltage Threshold
u003e= 0.15 Uc AC
Operating Time
20 ms at nominal voltage
Ambient Air Temperature For Storage
-40-85°C
Dielectric Strength
1500 V AC between contacts with micro disconnection, 2500 V AC between coil and contact with reinforced, 2000 V AC between poles with basic
[Ie] Rated Operational Current
10 A at 277 V AC conforming to UL, 10 A at 30 V DC conforming to UL, 10 A at 277 V AC (same polarity) conforming to CSA, 10 A at 30 V DC conforming to CSA, 5 A at 250 V AC (NC) conforming to IEC, 5 A at 28 V DC (NC) conforming to IEC, 10 A at 250 V AC (NO) conforming to IEC, 10 A at 28 V DC (NO) conforming to IEC
Range of Product
Harmony Electromechanical Relays
Minimum Switching Capacity
170 mW 10 mA, 17 V
Maximum Switching Capacity
2500 VA/280 W
Contacts Type And Composition
3 C/O
Switching Power
Max 2500 VA/280 W; Min 170 mW 10 mA, 17 V
Switching Voltage
250 V IEC
Current Rating
10 A at 277 V AC conforming to UL; 10 A at 30 V DC conforming to UL; 10 A at 277 V AC (same polarity) conforming to CSA; 10 A at 30 V DC conforming to CSA; 5 A at 250 V AC (NC) conforming to IEC; 5 A at 28 V DC (NC) conforming to IEC; 10 A at 250 V AC (NO) conforming to IEC; 10 A at 28 V DC (NO) conforming to IEC
Operating Temp. Range
-40-55°C
Country of Origin (subject to change)
China