Output Voltage
110/115/120V
Backup Time (Half/Full Load)
19 min/7 min
Fax/Modem Line Protection
No
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
Includes
PowerAlert Software and Cables
Special Features
Cold Start Operation Supported, Hot Swappable Batteries, Individually Controllable Load Banks
VA Rating - UPS Systems
2.2 kVA
NEMA Plug Configuration
5-15P
NEMA Receptacle Configuration
(7) 5-15R; (2) 5-15/20R
Ports
EPO, RS232, Slot for SNMPWEBCARD, USB
Footnotes
Slot for SNMPWEBCARD
Automatic Volts Regulation
Yes
Green Certification or Other Recognition
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
Capacity - Batteries
2200 VA/1600 W
Operating Temp. Range
104u0026deg;F (40u0026deg;C)
Battery Type
Sealed Lead Acid (SLA)
Input Connection
NEMA 5-15P Plug
Housing Material
Polycarbonate
UPS Input Cord Length (ft.)
8
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Primary UPS Height (mm)
361
PowerAlert Software
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
EMI / RFI AC Noise Suppression
Yes
Rated input current (Maximum Load)
16A
Audible Alarm
Audible alarm indicates power-failure, overload and low-battery conditions
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
Low Voltage Transfer to Battery Power (Setpoint)
79
AC Mode Efficiency Rating (100% Load)
0.94
Undervoltage Correction
Input voltages between 95 and 104 are boosted by 12%
Output Volt Amp Capacity (VA)
2200
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
Output kW Capacity (kW)
1.6
Output Voltage Regulation (Line Mode)
-2.25
Communications Cable
2 USB and 2 DB9 cables included
Communications Interface
Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB
Severe Undervoltage Correction
Input voltages between 79 and 94 are boosted by 24%
Audible Noise
Audible Noise u003c 47dBA At Front Side 1 Meter
High Voltage Transfer to Battery Power (Setpoint)
147
Nominal Input Voltage(s) Supported
120V AC
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Primary UPS Depth (mm)
305
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Full Load Runtime (min.)
7 min. (1600w)
UPS Power Module Dimensions (hwd, in.)
14.2 x 9.2 x 12
Load Management Receptacles
Three switchable two-outlet 5-15R load banks
High Availability UPS Features
Hot swappable batteries
Nominal Output Voltage(s) Supported
110V; 115V; 120V
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Individually Controllable Load Banks
Yes
UPS AC Suppression Response Time
Instantaneous
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 79V to 147V
Output Voltage Regulation (Battery Mode)
+/- 5%
Recommended Electrical Service
20A 120V
DC System Voltage (VDC)
48
UPS AC Suppression Joule Rating
480
Output AC Waveform (Battery Mode)
PWM sine wave
Network Management Cards
SNMPWEBCARD; TLNETCARD; WEBCARDLX
Overvoltage Correction
Input voltages between 128 and 147 are reduced by 12%
Frequency Compatibility
60 Hz
Internal UPS Replacement Battery Cartridge
RBC54
Relative Humidity
0 to 95%, non-condensing
Output Watt Capacity (Watts)
1600
Output kVA Capacity (kVA)
2.2
Input Circuit Breakers
20A
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Battery Recharge Rate (Included Batteries)
Less than 4 hours from 10% to 90% (typical, full load discharge)
Half Load Runtime (min.)
19 min. (800w)
Battery Replacement Description
Hot-swappable, user replaceable batteries
Battery Access
Battery access door
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Maximum Operating Temperature
104°F (40°C)
Battery Chemistry
Lead Acid
Package Contents
SmartPro SMART2200VS UPS, SMART 2200VS UPS System, PowerAlert Software and cabling, Warranty information, Instruction manual
Status Indicators
Includes 5 front panel LEDs to indicate BATTERY CHARGE LEVEL, AC LINE POWER STATUS, VOLTAGE REGULATION STATUS, UPS LOAD LEVEL and BATTERY LOW / REPLACE information
Network Management
SNMP Manageable
Load Capacity
2200 VA/1600 W
Typical Battery Recharge Time
4 Hour
Total Number of Expansion Slots
1
Alarm
Low Battery, Overload, On Battery
Certifications u0026 Standards
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications
Backup/Run Time (Half Load)
19 Minute
Package Includes
SMART 2200VS UPS System,;USB and DB9 Serial cabling;User manual
Output Capacity (Watts)
1600
Product Compliance
FCC Part 15 Class A (USA)
Product Certifications
CSA (Canada); NOM (Mexico); UL 1778
Installation Form Factors Supported with Included Accessories
Tower
UPS Applications
Large Network
Country of Origin (subject to change)
China