Center Line Pipe Center Size
2 13/16 in
Electrical Connections
1/2
Valve Design
2-Way/2-Position
Valve Configuration
Normally Closed
Body Material - Valves
Brass
Max. Fluid Temp.
180 Degrees F
Valve Ways and Positions
2-Way/2-Position
Max. Operating Pressure Differential Light Oil
100 psi
Max. Operating Pressure Differential Water
100 psi
NEMA Rating
1, 2, 3, 3S, 4, 4X
Environmental Rating - Valves
Indoor, Outdoor
Coefficient of Volume
0.73
Media
Air/Inert Gas, Light Oil and Water
Min. Operating Pressure Differential
0 psi
Seal Material - Valves
FKM
Max. Operating Pressure Differential Air/Inert Gas
100 psi
Coil Enclosure
Watertight No Junction Box
Standards
CE, CSA, FM, UL Listed
Application
Boilers, Burners, Car Wash Equipment, Compressors, Dishwashing and Laundry Equipment, Food Processing, Pumps
Operation Type
Direct Acting
Coefficient of Volume (Cv)
0.73
Operating Pressure Differential Light Oil - Maximum
100 psi
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Operating Pressure Differential Water - Minimum
Not Applicable
Outlet Connection Type
NPTF
Operating Pressure Differential - Minimum
0 psi
Operating Pressure Differential Steam - Minimum
Not Applicable
Ambient Temperature - Maximum
131 Degrees F
Fluid Temperature - Maximum
180 Degrees F
Inlet Connection Type
NPTF
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
Operating Pressure Differential Steam - Maximum
Not Rated
Valve Positions
2-Position
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Valve Starting Configuration
Normally Closed
Operating Pressure Differential Hot Water - Minimum
Not Applicable
For Media
Aggressive Gases, Aggressive Liquids, Air, Ammonia, Biodiesel Fuel, Cryogenic Fluids, Fuel Oil, Hot Water, Inert Gases, Light Oil, Liquid Propane Gas, Natural Gas, Oxygen, Steam, Water
Operating Pressure Differential Air/Inert Gas - Maximum
100 psi
Operating Pressure Differential Air/Inert Gas - Minimum
0 psi
Operating Pressure Differential Fuel Oil - Minimum
0 psi
Mounting Orientation
Horizontal or Vertical
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Operating Pressure Differential Light Oil - Minimum
Not Applicable
Operating Pressure Differential Fuel Oil - Maximum
100 psi
Operating Pressure Differential Water - Maximum
100 psi
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
Ambient Temperature - Minimum
-13 Degrees F
Environmental Rating
Corrosive, Hazardous, Indoor, Outdoor
Operating Pressure Differential Hot Water - Maximum
Not Rated
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Country of Origin (subject to change)
Mexico