For Use With
XCKD, XCKJ, XCKL , XCKM, XCKP, XCKS, XCR Limit Switches
AC Contact Rating
10 A @ 600 V
Standards
CSA, EC947-5-2, UL Listed, VDE 0660
Electrical Connection
Screw Terminal
NEMA Rating
1, 12, 2, 3, 4
Operating Temp.
-77 Degrees to 158 Degrees F
Minimum Actuation Speed
0.01 mm/s
Maximum Resistance Across Terminals
25 mOhm IEC 60255-7 category 3
Contacts Insulation Form
Zb
Contact Operation
snap action
Contacts Type And Composition
1 NO + 1 NC
Product Or Component Type
limit switch contact block
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Electrical Durability
5000000 cycles, DC-13 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Contacts Material
silver plated contacts
Product Compatibility
XCKJ || XCKM || XCKL || XCKD || XCR || XCKP || XCKS
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Series Name
standard format
Short-Circuit Protection
10 A cartridge fuse gG
Associated Body
ZCKJ1D || ZCD21 || ZCKM1 || ZCKJ1 || ZCKS1 || ZCP21 || ZCKL1
Compatible with Series
XCKD, XCKJ, XCKL, XCKM, XCKP, XCKS, XCR
Compatible Operator
Limit Switch
Terminal Connection Type
Screw Terminals
Country of Origin (subject to change)
France