Input Voltage
100 to 240V AC
Case Material
Plastic Case
Standards
IEC 62368-1, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, CSA C22.2 No 62368-1, UL 508, CSA C22.2 No. 107.1, EN/IEC 62368-1
Range of Product
Modicon Power Supply
Line And Load Regulation
u003c 0.5 % network 0 to 100 % load at 25°C, u003c 1 % network full voltage range in line at 25°C
Residual Ripple
u003c 75 mV
Efficiency
86 % 115 V AC, 88 % 230 V AC
Vibration Resistance
3 mm 2-9 Hz)IEC 60068-2-6, 10 m/s² 9-200 Hz)IEC 60068-2-6
Input Protection Type
integrated fuse (not interchangeable) 3.15 A, external protection (recommended) 20 A Curve C, external protection (recommended) 10 A Curve B, external protection (recommended) 6 A Curve C
Current Consumption
u003c 1.1 A 115 V AC, u003c 0.65 A 230 V AC
Mounting Support
top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail
Power Factor
0.45 at 115 V AC, 0.35 at 230 V AC
Holding Time
u003e 20 ms 100 V AC, u003e 100 ms 230 V AC
Status Led
1 LED (Green) output voltage
Output Coupling
parallel, serial
Ambient Air Temperature For Operation
-20--10°C with current derating of 2 % per°C mounting position A u003c 6561.68 ft (2000 m), -10-55°C without derating mounting position A u003c 6561.68 ft (2000 m), 55-70°C with current derating of 3.33 % per°C mounting position A u003c 6561.68 ft (2000 m)
Output Voltage Limits
24...28 V
Dielectric Strength
3000 V AC with input to output
Electromagnetic Compatibility
immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1
Operating Altitude
u003c 6561.68 ft (2000 m)
Power Supply Type
regulated switch mode
Supply
SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41
Power Supply Output Current
2.1 A
Inrush Current
35.0 A 115 V, 75.0 A 230 V
Shock Resistance
150 m/s² 11 ms
Power Dissipation In W
7.5 W
Maximum Leakage Current
1 mA 240 V AC
Electromagnetic Emission
conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4
Efficiency At Full Load
85...264 V AC
Network Frequency Limits
50-60 Hz
Electrical Shock Protection Class
class I
Meantime Between Failure [Mtbf]
2000000 h at 25°C, full load conforming to SR 332, 900000 h at 55°C, 80 % load conforming to SR 332
Output Protection Type
against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset
Earthing System
TN, TT, IT
Country of Origin (subject to change)
Thailand