Features
Contact Conversion without Removing Terminal Screws or Wires, Plug-in Contact Cartridges for Easy Contact Conversion and Replacement, Replaceable Coil, Self-Lifting Pressure Wire Connectors, Straight-Through Wiring
Overall Height - Relay
3.5 in
Power Consumption - Relay
23.0 VA
Body Height - Relay
3.5 in
AC Contact Rating - Relay
10A @ 120/240/480/600V
Body Depth - Relay
3.95 in
Item - Relay
NEMA Style Control Relay
DC Contact Rating - Relay
5A @ 125/250V
Body Width - Relay
2.23 in
Contact Amp Rating (Resistive)
10A
Contact Material
Silver Cadmium Oxide
Standards
CSA Certified, RoHS Compliant, UL Listed
Contact Form - Relay
(4) SPST-NO
Response Time
15 msec (Pick-Up Time), 16 msec (Drop-Out Time)
Hz - Electrical
50 Hz, 60 Hz
[Icm] Rated Short-Circuit Making Capacity
60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301 to 600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508
Product Certifications
UL listed file E78403 CCN NKCR || CSA LR60905 class 3211 03
Ambient Air Temperature For Operation
-40-160 °F
[Uc] Control Circuit Voltage
110 V AC 50 Hz || 120 V AC 60 Hz
Operating Time
15 ms - pick-up || 16 ms - drop-out
Tightening Torque
control circuit 1.02-1.36 N.m screw terminals
Rated Breaking Capacity
6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301 to 600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508
Control Circuit Voltage Limits
operational 0.85 to 1.1 Uc AC 50/60 Hz
Hold-In Power Consumption In Va
23-23 VA 60 Hz || 25-25 VA 50 Hz
Contacts Type And Composition
4 NO 4 standard contact cartridges
Line Rated Current
10 A AC || 5 A DC
Inrush Power In Va
148-148 VA 60 Hz || 143-143 VA 50 Hz
Product Or Component Type
relay
Electrical Connection
Screw Clamp
Awg Gauge
AWG 18 to AWG 12 copper
Minimum Operating Temperature
-40 Degrees F
Compatible with Series
8501 Type X Latching Control Relays
Contact Rating (AC)
10 A @ 600V
Maximum Operating Temperature
160 Degrees F
Contact Rating (DC)
0.2 A @ 301-600V, 0.55 A @ 250V, 0.8 A @ 250V, 1.1 A @ 125V, 4 A @ 125V
Country of Origin (subject to change)
Mexico