Promotion Restriction
Not eligible for promotion
Item - Infrared Thermometer
Infrared Thermometer
Focus Spot Size and Distance - Infrared
20 in @ 1 in
Temp. Range (F) - Infrared
-22 Degrees to 1112 Degrees
Temp. Range (C) - Infrared
-30 Degrees to 600 Degrees
Temp. Accuracy (F) - Infrared
+/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater
Temp. Accuracy (C) - Infrared
+/-1.0%
Laser Sighting - Infrared
Single Dot
Calibration Certificate Included
No
Data Logging - Instrument
Yes
Includes
Carabiner (62 Max+ Only)
Temperature Alarm - Thermometer
High, Low
Laser Sighting
Digital Camera
Spectral Response - Infrared
8.0 to 14.0um
Spectral Response
8.0 to 14 uM
Temp. Range (F)
-22 Degrees to 1112 Degrees F
Manufacturers Warranty Length
3 yr
Temp. Range (C)
-30 Degrees to 600 Degrees C
Calibration Certificate
No
Focus Spot Size and Distance
20
Repeatability
+/-0.5% of Reading
Emissivity
Adjustable 0.10 to 1.00
Operating Temp. Range
-22 Degrees to 1112 Degrees F
Special Features
99 Data Point Logging, High and Low Alarms for Rapid Display of Measurements Outside Set Limits, Small and Lightweight, Fits Easily Into Your Tool Box
Standards
Class II Laser, IEC 60825-1: Class 2, IEC 61010-1: Pollution Class 2, IEC 60529, Q/ASF01
Field of View
Not Applicable
Environmental Applications - Air Conditioners and Heat Pumps
Non-Medical
Features
IP54 Rated For Extra Protection Against Airborne Contaminants
Manufacturer Warranty Length
3 yr
Minimum Temperature Measured Degrees F
-22 Degrees F
Minimum Emissivity Setting
0.10
Mounting Style
Handheld Only
Maximum Temperature Measured Degrees F
1,112 Degrees F
Accuracy Degrees F
+/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater
Resolution Degrees F
0.2 Degrees F
Resolution Degrees C
0.1 Degrees C
Distance To Spot Ratio
20:1
Maximum Operating Temperature Degrees F
122 Degrees F
Alert Type
Digital Display, Sound
Maximum Emissivity Setting
1.00
Battery Chemistry
Alkaline
Digital Display Screen Type
LCD
Calibration Certificate Type
Not Certified
Includes Work Light
Work Light Included
Minimum Temperature Measured Degrees C
-30 Degrees C
Number of Batteries Required
1
Laser Sighting Type
Single Dot
Temperature Alerts
High Temperature, Low Temperature
Emissivity Adjustability
Adjustable
Minimum Operating Temperature Degrees F
32 Degrees F
Maximum Temperature Measured Degrees C
600 Degrees C
Accuracy Degrees C
+/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater
Testing Functions
Average, Difference, Maximum Temperature, Minimum Temperature
Secondary Measuring Method
No Secondary Measuring Method
Intrinsic Safety
Not Specified Intrinsically Safe
Country of Origin (subject to change)
China