Electrical Ratings
24 V AC
Includes
Boilers, Cooking and Laundry Equipment, Gas Furnaces, Infrared and Tube Heaters, Unit Heaters, Water Heaters
Product Type
Ignition Module
BtuH Capacity
Not Applicable
Electrical Connections
3/16 in Quick Connect
Lead Length (In.)
5 1/2 in
Igniter Warm-Up Time (Sec.)
90 sec
Type
Intermittent Pilot Ignition
Probe Length (In.)
Not Applicable
Retries
1, 2, 3, Continuous
For Use With
Residential and Commercial Heating Equipment
OEM Replacement Part Number
00-354447-00001, 00-857207-00001, 00-857207-00002, 025-27662-000, 025-27662-700, 025-29012-001, 025-29012-002, 025-29012-003, 025-29012-004, 025-42681-000, 031-01283-000, 03546, 05-162425-103, 05-162425-200, 05-162426-000, 05-162426-001, 05-162426-002, 05-162426-003, 05-162426-005, 05-162426-006, 05-162426-007, 05-162426-053, 05-162426-101, 05-162426-105, 05-162426-200, 05-162426-201, 05-162426-203, 05-162426-207, 05-162526-005, 05-169001-000, 05-169001-001, 05-169001-002, 05-169001-003, 05-169002-003, 05-169003-103, 05-169005-123, 05-169006-201, 05-169007-201, 05-169008-225, 05-169009-005, 05-169009-023, 05-169010-023, 05-169011-201, 05-169011-205, 05-169012-200, 05-169015-705, 05-169018-003, 05-203025-005, 05-203026-005, 05-272426-005, 05-272426-055, 05-272426-253, 05-279000-023, 05-279001-223, 05-279002-223, 05-279003-223, 05-279004-201, 05-279004-223, 05-279005-223, 05-296423-150, 05-296423-151, 05-296423-750, 05-296423-751, 05-296425-153, 05-296425-250, 05-296425-755, 05-296426-150, 05-296426-151, 05-296426-153
Maximum Input Current
800 mA
Application
Boilers, Ovens, LP/Natural Gas Furnaces, Infrared and Tube Heaters, Laundry, Unit Heaters, Water Heaters
Maximum Operating Temperature
175 Degrees F
Flame Sensor Current Output
0.5 uA
Probe Length
Not Applicable
Thermostat Anticipator Setting
Thermostat Anticipator
Igniter Warm Up Time
90 sec
Minimum Operating Temperature
-40 Degrees F
Pilot Valve Current Output
2 A
Electrical Connection Type
3/16 in Quick-Connect
Compatible with Brand
AAON, ADC, Bakers Pride, Baso, Beckett, BKI, Blodgett, Bradford White, Camstat, Capable, Carrier, Cleveland, Crown Stream, Dexter, Duke, Fenwal, Frymaster, Garland, Goodman, Groen, Henny Penny, Hobart, Honeywell, ICM, Johnson Controls, Laars, Lennox, Lincoln, Lochinvar, Midco, Middleby, Modine, Picard, Pitco, Resideo, Reznor, Rheem, Roberts Gordon, Robertshaw, Snyder, Space Ray, Sunstar, Superior Radiant, Trane, UTEC, Utica-Dunkirk, Vulcan Hart, Weil McLain, White-Rodgers, York
Low Voltage Protection
Low Voltage Protected
Board Type
Non-Integrated Board
Main Valve Current Output
4 A
Ignition Cycle Time
90 seconds (IP), 0 seconds (pre-purge), 0 seconds (inter-purge) 4 seconds (DS), 30 seconds (pre-purge), 30 seconds (inter-purge)
For Fuel Type
LP, Natural Gas
Country of Origin (subject to change)