Promotion Restriction
Not eligible for promotion
Item - Infrared Thermometer
Infrared Thermometer
Temp. Range
-40 Degrees to 1022 Degrees F
Focus Spot Size and Distance - Infrared
1 in @ 12 in
Temp. Range (F) - Infrared
-40 Degrees to 1022 Degrees
Temp. Range (C) - Infrared
-40 Degrees to 550 Degrees
Temp. Accuracy (F) - Infrared
+/-1.0% or +/-2.0 Degrees Whichever is Greater
Temp. Accuracy (C) - Infrared
+/-1.0%
Laser Sighting - Infrared
Single Dot
Calibration Certificate Included
Yes
Data Logging - Instrument
No
Display - IR Camera
Backlit LCD
Focus Spot Size and Distance
1
Emissivity
Adjustable 0.30, 0.70, 0.95
Repeatability
+/-0.5% of Reading or +/-2 Degrees F
Calibration Certificate
NIST
Operating Temp. Range
32 Degrees to 122 Degrees F
Spectral Response - Infrared
8.0 to 14.0um
Includes
Fabric Hook and Loop Fastener Pipe Probe, Hard Carrying Case, K Type Thermocouple
Manufacturers Warranty Length
2 yr
Memory - Instrument
Max., Min
Spectral Response
8.0 to 14 uM
Temp. Range (C)
-40 Degrees to 550 Degrees C
Temperature Alarm - Thermometer
High, Low
Temp. Range (F)
-40 Degrees to 1022 Degrees F
Field of View
Not Applicable
Environmental Applications - Air Conditioners and Heat Pumps
Non-Medical
Features
Contact and Non-Contact IR Thermometer for Measuring up Close or at a Distance, without a Ladder, Fabric Hook-and-Loop Fastener Pipe Probe for Superheat, Sub-Cooling, and other Contact and Ambient Measurements
Intrinsic Safety
Not Specified Intrinsically Safe
Alert Type
Digital Display
Digital Display Screen Type
LCD with Backlight
Accuracy Degrees F
+/-1.0% of Reading or +/-2.0 Degrees Whichever is Greater (Below 32 Degrees )
Maximum Operating Temperature Degrees F
120 Degrees F
Resolution Degrees C
0.1 Degrees C
Minimum Temperature Measured Degrees F
-40 Degrees F
Laser Sighting Type
Single Dot
Calibration Certificate Type
Traceable with data
Distance To Spot Ratio
12:1
Includes Work Light
Work Light Included
Testing Functions
Difference, Maximum Temperature, Minimum Temperature
Emissivity Adjustability
Adjustable
Maximum Temperature Measured Degrees C
550 Degrees C
Secondary Measuring Method
Type K Thermocouple
Accuracy Degrees C
+/-1.0% of Reading or +/1.0 Degrees Whichever is Greater
Minimum Emissivity Setting
0.30
Minimum Operating Temperature Degrees F
32 Degrees F
Maximum Temperature Measured Degrees F
1,022 Degrees F
Manufacturer Warranty Length
2 yr
Maximum Emissivity Setting
0.95
Minimum Temperature Measured Degrees C
-40 Degrees C
Resolution Degrees F
0.1 Degrees F
Number of Batteries Required
2
Country of Origin (subject to change)
China