Full Load Amps-Inductive
32 A
Item
IEC Magnetic Contactor
Full Load Amps-Resistive
50 A
HP @ 3 Phase - 208V
7 1/2 hp
Enclosure NEMA Rating
No Enclosure
Aux. Contact Configuration
1NO/1NC
Frame / Series / Class / Code
TeSys
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Auxiliary Contact Form
1NO/1NC
Switching Current
5 mA (Signalling Circuit)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Fuse Amps
10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Electrical Durability
1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V); 1.65 Mcycles (32 A, AC-3e, Less than 440 V)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Impulse Withstand Voltage
6 kV
Working Height
Up to 9842.52 ft
Thermal Amperage
10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Application
Motor Control, Resistive Load
Tightening Torque
1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Mechanical Durability
15 Mcycles
Rated Voltage
690V AC, 300V DC
Electrical Connection
Screw Clamp Terminals
Rated Insulation Volts
600/690V
Signalling Circuit Frequency
25 to 400 Hz
Switching Voltage
17 V (Signalling Circuit)
Operating Speed
3600 cycles per hr
Overvoltage Category
CAT III
Includes Protective Cover
Yes
Features
Without Built-In Suppressor Module
Rated Short-Time Withstand Current
260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Operating Watts
7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Shock Resistance
8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity
550 A @ 440V
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Terminal Connection Type
Screw Clamp Terminals
Horsepower @ Single Phase - 120V AC
2 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Three Phase - 208V AC
7 1/2 hp
Horsepower @ Single Phase - 240V AC
5 hp
Horsepower @ Three Phase - 240V AC
10 hp
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 600V AC
30 hp
Embedded Surge Suppressor
No
Number of Normally Open Main Contacts
3
Maximum Operating Temperature
140 Degrees F
Full Load Current - Inductive
32 A
NEMA Enclosure Rating
No Enclosure
Mechanical Operating Durability
15,000,000
Maximum Voltage Rating
690V AC
NEMA Enclosure Material
Not Applicable
Full Load Current - Resistive
50 A
Number of Auxillary Contacts
2
Horsepower @ Three Phase - 480V AC
20 hp
Reversing Capability
Non-Reversing
Electrical Operating Durability
1,400,000, 1,650,000
Includes Auxiliary Contacts
Yes
Minimum Operating Temperature
-40 Degrees F
Rated Short Time Withstand Current
260 A 104°F (40°C) - 10 s for power circuit; 430 A 104°F (40°C) - 1 s for power circuit; 60 A 104°F (40°C) - 10 min for power circuit; 138 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Insulation Resistance
Greater than 10 MOhm for signalling circuit
Rated Insulation Voltage
Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
IP Degree Of Protection
IP20 front face IEC 60529
Product Or Component Type
Contactor
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms)
Contactor Application
Resistive load; Motor control
Flame Retardance
V1 conforming to UL 94
Product Certifications
DNV; RINA; LROS (Lloyds register of shipping); CCC; CSA; GL; GOST; BV; UL; UKCA
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 63 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Pole Contact Composition
3 NO
Utilisation Category
AC-4; AC-1; AC-3; AC-3e
Protective Treatment
THIEC 60068-2-30
IRMS Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 550 A at 440 V for power circuit conforming to IEC 60947
Average Impedance
2 mOhm - Ith 50 A 50 Hz for power circuit
Minimum Switching Voltage
17 V for signalling circuit
Hold-In Power Consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Motor Power KW
7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3); 15 kW at 380 to 400 V AC 50/60 Hz (AC-3); 15 kW at 415 to 440 V AC 50/60 Hz (AC-3); 18.5 kW at 500 V AC 50/60 Hz (AC-3); 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3); 7.5 kW at 400 V AC 50/60 Hz (AC-4); 7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 15 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 15 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 18.5 kW at 500 V AC 50/60 Hz (AC-3e); 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Auxiliary Contact Composition
1 NO + 1 NC
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Rated Operational Current
32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Rated Impulse Withstand Voltage
6 kV IEC 60947
Power Dissipation Per Pole
2 W AC-3; 5 W AC-1; 2 W AC-3e
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Heat Dissipation
2 to 3 W at 50/60 Hz
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 50 A (at 140°F (60°C)) for power circuit
Control Circuit Type
AC 50/60 Hz standard
Minimum Switching Current
5 mA for signalling circuit
Mounting Support
Plate; Rail
Control Circuit Voltage
220 V AC 50/60 Hz
Maximum Horse Power Rating
2 hp at 115 V AC 50/60 Hz for 1 phase motors; 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Connections - Terminals
Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1.5 to 10 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: solid without cable end
Country of Origin (subject to change)
Indonesia