Events Available - Electronic Timer
96
Available Actions - Electronic Timer
On/Off
Operating Temp.
-40 Degrees to 155 Degrees F
Event Allocation - Electronic Timer
1 On/Off Action = 2 Events
Standards
California Title 20 Listed, LED Listed, UL Listed
Description/Special Features
Outdoor
Enclosure Type
Indoor/outdoor type 3R plastic with see-through door
Features
100-hour supercapacitor eliminates the need for batteries; Up to 96 set points or events; Up to 50 holiday blocks with schedule capabilities; Automatic input voltage selection from 120 to 277 VAC, 60 Hz; Additional mode of operation turns the ON/OFF buttons into 2-hour overrides; Configurable outputs allow the control of various voltages and applications; Relays incorporate zero-crossing technology to extend the life of the control; Non-volatile EEPROM memory protects programming indefinitely; LED compatible; USB port makes transferring and saving of schedules easy
Max. Ballast Amps
10 A, 120/277 VAC
Application
Commercial, Industrial, Utility, Lighting Control, Energy Savings, Comfort u0026 Convenience, Machinery u0026 Pumps, Indoor Lighting Control, Timing/Scheduling ON/OFF, Machinery u0026 Pump Controls, Interior Lighting, Exterior Lighting, Electric Pumps, Electric Motor Control, Various Other Electrical Loads
Maximum ON/OFF Times
Indefinite
Inductive Load Ratings NC Ranges
10 A, 120-240 VAC
Electronic Ballast Load Ratings NO Ranges
10 A, 120/277 VAC
Magnetic Ballast (NC) Range(s)
3 A, 120-277 VAC
Electronic Series
ET2000 Series
Operation Features
Holiday
Motor Load Ratings NC Ranges
1/4 HP, 120 VAC; 1/2 HP, 240 VAC
Minimum ON/OFF Times
1 min
Inductive Load Ratings NO Ranges
20 A, 120-240 VAC
Daylight Savings Adjustment
Automatic
Knockout Dimensions Bottom
(2) combination 1/2
Voltage Selection Type
Auto Voltage
Resistive (NC) Range(s)
10 A, 28 VDC; 10 A, 120-240 VAC
Backup Protection Time
100 Hour
Backup Type
Supercapacitor
Knockout Dimensions Back
(1) combination 1/2
Magnetic Ballast (NO) Range(s)
20 A, 120-277 VAC
Maximum ON/OFF Operations
96
Applications
Indoor Lighting ControlnMachinery u0026 Pump ControlsnTiming/Scheduling ON/OFF
Backup Restoration Time
30 Minutes
Maximum Power Consumption (W)
3 W
Operating Temperature Max (°F)
104
Electronic Ballast LED
10A
Motor Load Ratings NO Ranges
1 HP, 120 VAC; 2 HP, 240 VAC
Input Voltage Range(s)
120-277 VAC, 60 Hz
Resistive (NO) Range(s)
20 A, 28 VDC; 20 A, 120-240 VAC
Operating Temperature Min (°F)
-40
Application Compatibilities
LED
Operating Temperature Max (°F)
104
Operating Temperature Min (°F)
-40
Country of Origin (subject to change)
Mexico