Item
Electromechanical Timer
Enclosure Type
Polycarbonate
Nominal Max. Time Setting
24 hr
Number of Trippers Included
4
Time Setting Range
1 hr. to 23 hr.
Operating Temp.
-40 Degrees to 130 Degrees F
Extra Trippers
Mfr. No. 156T1978A
Description/Special Features
Clear Plastic Door
Tungsten Load Ratings
40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
Application Compatibilities
LED; HID
Product Depth
4 in; 101.6 mm
Input Voltage Ranges
208-277 VAC, 60 Hz
Minimum On Off Time
1 hour
Product Height
10 in; 254 mm
Tungsten Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Electronic Ballast Load Ratings Ranges
16 A, 120-277 VAC
Solutions
Machinery u0026 Pumps; Panel Integrators
Packaging Applications
Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps
Has Manual Override CVL
Yes
Inductive Load Ratings
40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
UL Cerfication File Number
UL917
Product Width
6 1/2 in; 165.1 mm
Electronic Ballast Load Ratings
16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC
Resistive Load Ratings Ranges
40 A, 120-480 VAC, 60 Hz
Resistive Load Ratings
40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz; 40 A, 347 VAC, 60 Hz
Applications
Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control
Power Consumption Max W
3 W
Pilot Duty Load Ratings Ranges
1000 VA, 120-277 VAC, 60 Hz
Inductive Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Knockout Dimensions Back
(1) combination 1/2
Knockout Dimensions Bottom
(2) combination 1/2
Pilot Duty Load Ratings
1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz
Maximum On Off Operations
12
Operating Temperature Max
130°C
Motor Load Ratings
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Operating Temperature Min
-40°C
Skipper Wheel Operation Mode
Not Included
Market
Commercial; Industrial
Inductive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
Resistive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz
Tungsten (NO)
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
Input Voltage Range(s)
208-277 VAC, 60 Hz
Skipper Wheel
Not Included
Operating Temperature Min (°F)
-40
Electronic Ballast
16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC
Motor Load Ratings Ranges
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Features
Direct 24-hour control of most loads; Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour; Manual override; One ON and one OFF tripper included
Pilot Duty (NO)
1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz
Maximum Power Consumption (W)
3 W
Maximum ON/OFF Operations
12
Operating Temperature Max (°F)
130
Tungsten Range(s)
40 A, 120-277 VAC, 60 Hz
Minimum ON/OFF Times
1 hour
Operating Temperature Min (°F)
-40
Operating Temperature Max (°F)
130
Country of Origin (subject to change)
Mexico