Promotion Restriction
Not eligible for promotion
Item
Electric Tankless Water Heater
Water Heater Design
Point-of-Use
Water Heater Application
Emergency Eye, Face u0026 Drench Showers
Commercial / Residential
Commercial
Min. Flow Activation
2.50 gpm
Temp. Rise @ 6.0 GPM
Limited to Thermostatic Setting
Temp. Rise @ 4.0 GPM
Limited to Thermostatic Setting
Temp. Rise @ 2.5 GPM
Limited to Thermostatic Setting
Elements
Lead-Free Replaceable Cartridge Insert
Temp. Rise @ 20.0 GPM
49 Degrees F
Standards
UL 499, CSA, Compliance Certified for Use In Potable Water Applications, Low Lead Certified to NSF372
Features
Fine Tuned Control Board with Temp/Pressure/Flow Algortithm, Speed to Temperature, Low Hysteresis, Low Pressure Drop, Minimal Diagnostics, and Temperature Overshoot, Dry Fire Safety Sensor, Temp Accuracy: +/-1 Degrees at Steady State Flow, Emergency Eye, Face u0026 Drench
Residential / Commercial
Commercial
Default Temperature
120 Degrees F
Temp. Rise @ 8.0 GPM
122 Degrees F
Temp. Range
60 Degrees to 90 Degrees F
Power Consumption
144,000 W
Maximum Water Pressure
150 psi
Minimum Water Pressure
35 psi
Application
Emergency Eye, Face and Drench
Market
Commercial, Industrial
Temperature Rise @ Flow
33 Degrees F @ 30 gpm, 38 Degrees F @ 26 gpm, 43 Degrees F @ 23 gpm, 49 Degrees F @ 20 gpm
Maximum Delivered Temperature
90 Degrees F
Minimum Delivered Temperature
80 Degrees F
Control Type
Digital Display with Keypad
Cord Conductor Gauge
2/0 AWG Wire
Water Connection Location
Bottom
Housing Material Finish
Powder Coated
Element Material
Non-Ferrous Metal
Minimum Flow Activation
2.5 gpm
Country of Origin (subject to change)
United States